25A C Curve B-HP RCBO Heat Pump Consumer Unit
25A C Curve B-HP RCBO Heat Pump Consumer Unit from WCED Whitecliffe, model WME06/HP25C, combines dedicated heat pump protection, two separately protected auxiliary circuits and Type 2 surge protection in a 6-module enclosure.
Meets Vaillant’s High-Frequency Protection Requirements
The dedicated 25A C Curve Type B-HP RCBO meets Vaillant’s published residual-current protection requirements: Type B protection rated to at least 20 kHz, with a minimum tripping threshold of 150 mA at frequencies above 1 kHz. The RCBO’s 30 mA rated residual operating current and the 150 mA minimum threshold above 1 kHz describe its response under different conditions.
Use this board where the exact Vaillant heat pump model and circuit design call for 25A C Curve overcurrent protection. The 25A rating and C Curve describe the overcurrent side of the RCBO, while Type B-HP describes its residual-current protection. See the Vaillant aroTHERM plus installer’s quick guide.
Why Some Heat Pumps Need Type B-HP
Inverter-driven heat pumps use electronic switching to vary compressor speed. The inverter and its filters can produce high-frequency earth leakage during normal operation, and certain faults can produce smooth DC residual current. Type B protection detects smooth DC residual fault currents. The B-HP device also has a defined high-frequency tripping response, which helps reduce unwanted trips from normal inverter leakage while providing the protection specified for the equipment.
When Is Standard Type B Suitable?
A standard Type B device can be suitable for other heat pumps where the manufacturer permits it and the device meets the requirements for that model. If the installation instructions specify a frequency range or tripping threshold, check those figures against the protective device’s datasheet.
What’s Included in the WCED WME06/HP25C?
- 1 x WCED WME06 6-module consumer unit enclosure
- 1 x 25A C Curve Type B-HP RCBO for the dedicated heat pump circuit
- 2 x 16A B Curve Type A RCBOs for auxiliary circuits
- 1 x Type 2 surge protection device (SPD)
- 1 x main switch isolator
Separate Protection for Auxiliary Circuits
The two fixed 16A B Curve Type A RCBOs can protect separate circuits for associated loads, such as controls or an immersion heater, where the load and circuit design suit the device. The Type 2 SPD helps protect connected equipment from transient overvoltages.
Dedicated Heat Pump RCBO Specifications
- Rated current and overcurrent trip curve: 25A, C Curve
- Residual-current protection: Type B-HP
- Rated residual operating current: 30 mA
- Rated breaking capacity: 10 kA
- Pole configuration: 1P+N with switched live and neutral
- Operation: Bi-directional
- Mounting: 18 mm single module on 35 mm DIN rail