VAT:

WCED | WME06/HP25C | B-HP RCBO Heat Pump Consumer Unit | 25A C Curve | Type 2 SPD | 2 x 16A Type A RCBOs

SKU: WME06/HP25C
1 In Stock
More available within:
Usually 1 - 2 Working Days
Read More

WCED WME06/HP25C heat pump consumer unit with a 25A C Curve Type B-HP RCBO that meets Vaillant’s requirements: at least 20 kHz and a minimum 150 mA trip threshold above 1 kHz. Includes a Type 2 SPD and two 16A B Curve Type A RCBOs.

£ 128 .50 EX VAT
£ 154 .20 IN VAT
OR

25A C Curve B-HP RCBO Heat Pump Consumer Unit

25A C Curve B-HP RCBO Heat Pump Consumer Unit from WCED Whitecliffe, model WME06/HP25C, combines dedicated heat pump protection, two separately protected auxiliary circuits and Type 2 surge protection in a 6-module enclosure.

Meets Vaillant’s High-Frequency Protection Requirements

The dedicated 25A C Curve Type B-HP RCBO meets Vaillant’s published residual-current protection requirements: Type B protection rated to at least 20 kHz, with a minimum tripping threshold of 150 mA at frequencies above 1 kHz. The RCBO’s 30 mA rated residual operating current and the 150 mA minimum threshold above 1 kHz describe its response under different conditions.

Use this board where the exact Vaillant heat pump model and circuit design call for 25A C Curve overcurrent protection. The 25A rating and C Curve describe the overcurrent side of the RCBO, while Type B-HP describes its residual-current protection. See the Vaillant aroTHERM plus installer’s quick guide.

Why Some Heat Pumps Need Type B-HP

Inverter-driven heat pumps use electronic switching to vary compressor speed. The inverter and its filters can produce high-frequency earth leakage during normal operation, and certain faults can produce smooth DC residual current. Type B protection detects smooth DC residual fault currents. The B-HP device also has a defined high-frequency tripping response, which helps reduce unwanted trips from normal inverter leakage while providing the protection specified for the equipment.

When Is Standard Type B Suitable?

A standard Type B device can be suitable for other heat pumps where the manufacturer permits it and the device meets the requirements for that model. If the installation instructions specify a frequency range or tripping threshold, check those figures against the protective device’s datasheet.

What’s Included in the WCED WME06/HP25C?

  • 1 x WCED WME06 6-module consumer unit enclosure
  • 1 x 25A C Curve Type B-HP RCBO for the dedicated heat pump circuit
  • 2 x 16A B Curve Type A RCBOs for auxiliary circuits
  • 1 x Type 2 surge protection device (SPD)
  • 1 x main switch isolator

Separate Protection for Auxiliary Circuits

The two fixed 16A B Curve Type A RCBOs can protect separate circuits for associated loads, such as controls or an immersion heater, where the load and circuit design suit the device. The Type 2 SPD helps protect connected equipment from transient overvoltages.

Dedicated Heat Pump RCBO Specifications

  • Rated current and overcurrent trip curve: 25A, C Curve
  • Residual-current protection: Type B-HP
  • Rated residual operating current: 30 mA
  • Rated breaking capacity: 10 kA
  • Pole configuration: 1P+N with switched live and neutral
  • Operation: Bi-directional
  • Mounting: 18 mm single module on 35 mm DIN rail

Related Heat Pump Circuit Protection

Browse our heat pump consumer units for other board configurations or view our individual heat pump RCBOs for alternative ratings and trip curves.






Brand

WCED

Cut off time for Dispatch Delivery: Mon-Thu 3 PM *
All orders placed on Sat/Sun will be dispatched on Monday.