VAT:

Circuit Protection

Showing 2221–2240 of 2483 results

Live Electrical RNC125C-030N C Curve RCBO 25A

Live Electrical | RNC125C-030N | 6kA 30mA | Type A | Curve C | Bi-Directional Double Pole RCBO | 25A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: RNC125C-030N
£9.75
Live Electrical RNC132C-030N C Curve RCBO 32A

Live Electrical | RNC132C-030N | 6kA 30mA | Type A | Curve C | Bi-Directional Double Pole RCBO | 32A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: RNC132C-030N
£9.75
Live Electrical RNC140C-030N C Curve RCBO 40A

Live Electrical | RNC140C-030N | 6kA 30mA | Type A | Curve C | Bi-Directional Double Pole RCBO | 40A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: RNC140C-030N
£9.75

FuseBox | DRISO323P | 3 Pole DIN Rail Isolator Switch | AC-23A | 32A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: DRISO323P
£12.98

FuseBox | FRIS4P020 | 4 Pole AC Rotary Isolator | IP65 | 20A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: FRIS4P020
£11.92

FuseBox | FRIS4P080 | 4 Pole AC Rotary Isolator | IP65 | 80A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: FRIS4P080
£39.08

FuseBox | FRIS4P100 | 4 Pole AC Rotary Isolator | IP65 | 100A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: FRIS4P100
£48.36
SPD1 Type 2 & 3 Single Phase SPD

Surge Protection Devices | SPD1 | Type 2 & 3 Single Phase SPD | 40kA

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
£31.95
Choose options
This product has multiple variants. The options may be chosen on the product page
SPD2 Type 2 & 3 Single Phase SPD

Surge Protection Devices | SPD2 | Type 2 & 3 Single Phase SPD | 40kA

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
£74.95
Choose options
This product has multiple variants. The options may be chosen on the product page
SPD4 Type 2 & 3 Three Phase SPD

Surge Protection Devices | SPD4 | Type 2 & 3 Three Phase SPD | 40kA

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
£138.95
Choose options
This product has multiple variants. The options may be chosen on the product page
LSPD22 Type 1 2 3 Single Phase SPD

Surge Protection Devices | LSPD22 | Type 1, 2 & 3 Single Phase SPD | 12.5kA Per Pole

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
£150.95
Choose options
This product has multiple variants. The options may be chosen on the product page
LSPD12 Type 1 2 3 Single Phase SPD

Surge Protection Devices | LSPD12 | Type 1, 2 & 3 Single Phase SPD | 25kA Per Pole

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
£232.95
Choose options
This product has multiple variants. The options may be chosen on the product page
LSPD14 Type 1 2 3 Three Phase SPD

Surge Protection Devices | LSPD14 | Type 1, 2 & 3 Three Phase SPD | 25kA Per Pole

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
£455.95
Choose options
This product has multiple variants. The options may be chosen on the product page
LSPDPV1500 Type 1+2 1500V DC PV SPD

Surge Protection Devices | LSPDPV1500 | Type 1+2 PV SPD | 1500V DC

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: LSPDPV1500
£188.95
Deligo | TC24HR | 24 Hour DIN Rail Time Clock | 15 Min Segment

Deligo | TC24HR | 24 Hour DIN Rail Time Clock | 15 Min Segment

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: TC24HR
£17.71
Deligo | EMFT | 12-240V AC/DC Multi Function Timer | 16ADeligo | EMFT | 12-240V AC/DC Multi Function Timer | 16A

Deligo | EMFT | 12-240V AC/DC Multi Function Timer | 16A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: EMFT
£19.01
Deligo | TC7D2 | 2 Channel 7 Day Time Clock | 16A | Battery BackupDeligo | TC7D2 | 2 Channel 7 Day Time Clock | 16A | Battery Backup

Deligo | TC7D2 | 2 Channel 7 Day Time Clock | 16A | Battery Backup

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: TC7D2
£37.54
Deligo | TC7D | 1 Channel 7 Day Time Clock | 16A | Battery BackupDeligo | TC7D | 1 Channel 7 Day Time Clock | 16A | Battery Backup

Deligo | TC7D | 1 Channel 7 Day Time Clock | 16A | Battery Backup

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: TC7D
£26.23
Hager | L50600 | 1P+N Fuse Carrier | 32A 400V | 10x38Hager | L50600 | 1P+N Fuse Carrier | 32A 400V | 10x38

Hager | L50600 | 1P+N Fuse Carrier | 32A 400V | 10×38

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: L50600
£8.76
Hager | LS701 | 1P Fuse Carrier | 125A 690V | 22x58Hager | LS701 | 1P Fuse Carrier | 125A 690V | 22x58

Hager | LS701 | 1P Fuse Carrier | 125A 690V | 22×58

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: LS701
£36.87

Showing 2221–2240 of 2483 results

Selection of Consumer Units, TPN Distribution Boards, Circuit Protection, Rotary Isolators, Meter Tails, Fused Switches and Accessories.

18th Edition Consumer Units with built in SPD Surge Protection Device, stand alone SPD units, PEN loss, PME fault detection consumer units, Consumer units relocation boxes/kits, Three phase distribution boards with built in SPD and main switch.

Thousands of products in stock ready for next day delivery. Friendly and reliable service, competitive prices.

Circuit protection in the UK is governed by the wiring regulations outlined in the British Standard BS 7671. This standard, also known as the IET Wiring Regulations, sets out the requirements for the design, installation, and maintenance of electrical installations in the UK. Circuit protection is a crucial aspect of electrical installations to ensure the safety of people and property.

Here are some key aspects of circuit protection according to BS 7671 and the devices commonly used in the UK market:

  1. Circuit Breakers: Circuit breakers are essential devices for protecting electrical circuits. BS 7671 specifies requirements for the selection and installation of circuit breakers. They come in various types, including:
    • Miniature Circuit Breakers (MCBs): MCBs are commonly used to protect individual circuits. They trip when there’s an overload or a short circuit.
    • Residual Current Devices (RCDs): RCDs are designed to protect against electric shock. They disconnect the circuit if they detect an imbalance in current, indicating a fault.
    • Combination RCD/MCB Devices: These devices combine the functions of both MCBs and RCDs in a single unit. They are often used for socket outlets.
  2. Fuses: While less common in modern installations, fuses may still be used for circuit protection. They work by melting when there’s an excess current, breaking the circuit.
  3. Overcurrent Protection: BS 7671 requires that circuits are protected against overcurrents. This is typically achieved through the use of circuit breakers, fuses, or other protective devices.
  4. Earthing and Bonding: Proper earthing and bonding are essential for safety. This ensures that in the event of a fault, the fault current is safely directed away from people and property.
  5. Surge Protection: Surge protection devices may be required to protect against voltage surges or lightning strikes, especially for sensitive electronic equipment.
  6. Arc Fault Detection: In certain installations, arc fault detection devices may be used to detect and disconnect circuits in the presence of dangerous arc faults.
  7. Circuit Isolation: BS 7671 also specifies requirements for circuit isolation devices such as switches and isolators.
  8. Cable Sizing: The standard provides guidelines for selecting the correct cable size to ensure that the cables can safely carry the intended load without overheating.
  9. Circuit Labels and Documentation: Proper labeling and documentation of circuits are important for maintenance and safety. BS 7671 outlines requirements for labeling and record-keeping.

It’s important to note that regulations and standards may be updated over time, so it’s essential to consult the latest version of BS 7671 and any local regulations or codes that may apply to your specific location or type of installation. Additionally, electrical work should be carried out by qualified and competent electricians to ensure compliance with safety standards.