WCED WRB110B-030 Bi-Directional RCBO
The WCED WRB110B-030 Bi-Directional RCBO is a 10A B Curve protective device from the Whitecliffe Electrical WRB1 range, designed to combine overload, short-circuit and residual current protection within a compact single-module housing. With 30mA Type A high-immunity detection and a 6kA breaking capacity, it provides an efficient solution for individual circuit protection in compatible consumer units.
Its 10A rating and B Curve characteristic make it an option for appropriately designed circuits with relatively low inrush currents. The WRB110B-030 also features bi-directional capability, allowing it to be considered for compatible solar photovoltaic installations where power flow may vary.
Key Features
- 10A rated current with B Curve tripping characteristic
- Type A high-immunity residual current protection
- 30mA residual operating sensitivity
- 6kA rated short-circuit breaking capacity
- Bi-directional design for suitable solar PV applications
- 1P+N configuration with switched live and neutral
- Single-module construction, approximately 18mm wide
- Electronic residual current detection with thermal-magnetic overcurrent release
- Bi-connect terminals for compatible cable and busbar connections
- Contact position indicator
- Mounting on a standard 35mm DIN rail
- IEC 61009-1 and EN 61009-1 standards
10A B Curve Protection for Lower-Current Circuits
The WRB110B-030 provides a 10A rating with a B Curve tripping characteristic, generally used where starting or inrush currents are relatively low. Potential applications include suitably rated lighting circuits, fixed electrical equipment and other appropriately designed final circuits.
The combined RCBO arrangement provides residual current and overcurrent protection for one circuit, helping limit disruption to unaffected circuits when a fault occurs.
Bi-Directional Operation for Solar PV Installations
The WCED WRB110B-030 Bi-Directional RCBO belongs to the manufacturer’s WRB1 range, developed for bi-directional use in electrical installations.
This design can be advantageous for selected solar PV applications where electricity may flow in more than one direction. Protective device selection must consider the characteristics of the inverter, circuit arrangement and applicable installation requirements.
WCED specifies connection from the bottom, and installers should always follow the manufacturer’s terminal markings and wiring instructions.
Type A High-Immunity Residual Current Detection
The WRB110B-030 detects sinusoidal AC and pulsating DC residual fault currents, providing Type A protection for suitable modern electrical equipment. This offers broader residual current detection than conventional Type AC devices.
Its 30mA residual current sensitivity provides additional protection against electric shock when correctly selected and installed. The manufacturer’s high-immunity designation is part of the WRB1 range specification.
Switched Live and Neutral
With a 1P+N configuration, the WRB110B-030 incorporates switched live and neutral contacts. Both conductors disconnect when the protective device operates, allowing the affected circuit to be isolated separately from other circuits.
The switched-neutral design can also assist certain insulation resistance testing procedures, subject to the selected test method and equipment connected to the circuit.
Single-Module Installation and Bi-Connect Terminals
The RCBO occupies approximately 18mm of DIN rail space, making it suitable for compatible consumer units and distribution boards where compact circuit protection is required.
Bi-connect terminals allow connection using suitable cables, pin-type busbars and fork/U-type busbars. The manufacturer specifies 2.5Nm tightening torque and mounting on an EN 60715 35mm DIN rail.
Technical Specifications
- Brand: WCED Whitecliffe Electrical
- Manufacturer Part Number: WRB110B-030
- Product Range: WRB1
- Product Type: Electronic Bi-Directional RCBO
- Rated Current: 10A
- Tripping Characteristic: B Curve
- Residual Current Classification: Type A High Immunity
- Rated Residual Operating Current: 30mA
- Rated Breaking Capacity: 6kA
- Number of Poles: 1P+N (Switched Live and Neutral)
- Rated Operational Voltage: 230V AC
- Rated Frequency: 50/60Hz
- Rated Insulation Voltage: 500V
- Rated Residual Making and Breaking Capacity: 3000A
- Rated Impulse Withstand Voltage: 4kV
- Residual Current Break Time at IΔn: ≤0.1 seconds
- Dielectric Test Voltage: 2kV for 1 minute
- Pollution Degree: 2
- Electrical Endurance: 2,000 operations
- Mechanical Endurance: 10,000 operations
- Contact Position Indicator: Yes
- Protection Rating: IP20
- Reference Temperature: 30°C
- Operating Temperature: -5°C to +40°C
- Storage Temperature: -25°C to +70°C
- Top Cable Terminal Capacity: 10mm²
- Bottom Cable Terminal Capacity: 16mm²
- Busbar Terminal Capacity: 10mm²
- Terminal Tightening Torque: 2.5Nm
- Mounting: DIN Rail EN 60715 (35mm)
- Manufacturer-Specified Connection: From Bottom
- Applicable Standards: IEC 61009-1 / EN 61009-1
Other WCED B Curve Bi-Directional RCBOs
Explore alternative ratings in the WCED WRB1 B Curve range:
- WCED WRB106B-030 – 6A B Curve RCBO
- WCED WRB116B-030 – 16A B Curve RCBO
- WCED WRB120B-030 – 20A B Curve RCBO
- WCED WRB132B-030 – 32A B Curve RCBO
- WCED WRB140B-030 – 40A B Curve RCBO
Explore WCED Whitecliffe Circuit Protection
Browse our WCED Consumer Units or discover the complete WCED Whitecliffe product range at Electrical4Less.
Before installation, verify compatibility with the selected consumer unit, circuit design and connected equipment. All protective device selection and installation work must comply with applicable electrical installation requirements.