Niglon MS4CBR-400TSM 400A 4 Pole Enclosed CBR – MCCB + RCD Protection
The Niglon MS4CBR-400TSM 400A 4 Pole Enclosed CBR is a heavy-duty circuit protection assembly designed for three-phase commercial and industrial power distribution. Combining a four-pole moulded case circuit breaker (MCCB) with residual current protection, it provides overload, short-circuit and earth leakage protection within a mild steel enclosure.
With a rated current of 400A and a 400/415V AC operational voltage, the enclosed CBR is suitable for higher-capacity electrical distribution applications. Adjustable thermal protection, selectable earth leakage sensitivity and time-delay settings allow protective characteristics to be selected according to the installation requirements.
400A MCCB with Integrated Residual Current Protection
The Niglon MS4CBR-400TSM combines two important protective functions within one assembly. The MCCB provides protection against overload and short-circuit conditions, while the integrated residual current function detects earth leakage faults exceeding the selected threshold.
This combined arrangement is particularly useful for three-phase distribution systems requiring both circuit protection and adjustable earth fault protection without installing separate MCCB and RCD devices.
Adjustable Earth Leakage Sensitivity
The residual current protection offers three selectable sensitivity settings:
- 100mA: For applications requiring the lowest available residual current threshold on this device.
- 300mA: For installations designed around a 300mA earth leakage protection threshold.
- 500mA: For applications where a higher residual current threshold is specified.
Selectable time-delay settings of 50ms, 500ms and 800ms provide additional flexibility when coordinating protective devices within a distribution system.
Final settings must be selected according to the installation’s earthing arrangements, fault protection requirements and protective device coordination.
Adjustable Thermal and Short-Circuit Protection
The 400A four-pole CBR incorporates adjustable thermal overload protection and fixed magnetic short-circuit protection, as specified in the manufacturer’s 4CBR-400 device datasheet.
The associated CBR device has a rated breaking capacity of 35kA at 415V AC and a rated ultimate short-circuit breaking capacity of 50kA at 400V AC.
These characteristics make the device suitable for consideration in higher-current electrical distribution systems, subject to prospective fault current calculations and installation design.
IP30 Mild Steel Enclosure
The Niglon MS4CBR-400TSM 400A 4 Pole Enclosed CBR is supplied within a durable mild steel enclosure, providing protection for the enclosed switchgear in suitable indoor environments.
The enclosure features a RAL7035 light grey epoxy powder-coated finish and an IP30 ingress protection rating when correctly installed.
A defeatable, padlockable operating handle provides external circuit breaker operation and allows the handle to be secured as part of appropriate isolation procedures.
Key Features
- 400A four-pole enclosed CBR for three-phase distribution.
- Combined MCCB and residual current protection.
- 400/415V AC rated operational voltage.
- 50/60Hz operating frequency.
- Adjustable thermal overload protection.
- Fixed magnetic short-circuit protection.
- 35kA rated breaking capacity at 415V for the associated CBR device.
- 50kA ultimate short-circuit breaking capacity at 400V AC for the associated CBR device.
- Selectable 100mA, 300mA and 500mA earth leakage thresholds.
- Adjustable residual current time delay: 50ms, 500ms and 800ms.
- IP30 mild steel enclosure.
- RAL7035 epoxy powder-coated finish.
- Defeatable, padlockable operating handle.
- Suitable for commercial and industrial electrical distribution.
Technical Specifications
| Manufacturer | Niglon |
|---|---|
| Product Code | MS4CBR-400TSM |
| Product Type | Enclosed CBR (MCCB + RCD) |
| Number of Poles | 4 Pole |
| Rated Current | 400A |
| Rated Operational Voltage | 400/415V AC |
| Rated Frequency | 50/60Hz |
| Rated Insulation Voltage | 750V |
| Rated Impulse Withstand Voltage | 8kV |
| Associated CBR Breaking Capacity | 35kA at 415V AC |
| Associated CBR Ultimate Breaking Capacity | 50kA at 400V AC |
| Thermal Protection | Adjustable |
| Magnetic Protection | Fixed (4CBR-400 datasheet) |
| Residual Current Sensitivity | 100 / 300 / 500mA |
| Residual Current Time Delay | 50 / 500 / 800ms |
| Mechanical Endurance | 7,000 Operations |
| Electrical Endurance | 1,000 Operations |
| Enclosure Material | Mild Steel |
| Enclosure Protection | IP30 |
| Enclosure Finish | Epoxy Powder Coated |
| Enclosure Colour | RAL7035 Light Grey |
| CBR Standard | IEC 60947-2 |
| Enclosure Standards | IEC 61439-1, IEC 62208, IEC 60529, IEC 62262 |
Typical Applications
The Niglon MS4CBR-400TSM 400A 4 Pole Enclosed CBR is suitable for consideration in higher-capacity electrical installations requiring combined overload, short-circuit and residual current protection.
- Industrial three-phase electrical distribution.
- Commercial main and sub-main distribution systems.
- Electrical plant rooms and switchgear installations.
- High-current fixed equipment supplies.
- Distribution circuits requiring adjustable earth leakage protection.
Installation and Safety
Installation and commissioning must be undertaken by suitably qualified electrical personnel in accordance with applicable UK electrical installation regulations.
The protective device rating, residual current threshold and time-delay settings must be appropriate for the installation design, prospective fault current and protection coordination requirements.
Important: The minimum selectable residual current sensitivity is 100mA. This unit does not provide 30mA additional protection where that level of protection is required.
Correct cable glands must be used to maintain the enclosure’s ingress protection rating. All electrical terminals, including factory-fitted connections, must be checked for correct tightness before commissioning.