Hager ASY450U 50A C Curve 100mA RCBO is a 10kA electronic 3P+N switched-neutral, three-module RCBO with Type A 100mA residual-current protection. C-curve response suits appropriately designed moderate-inrush circuits.

Hager ASY450U 50A C Curve 100mA RCBO

The Hager ASY450U 50A C Curve 100mA RCBO integrates the functions of a circuit breaker and residual-current device with a 100mA setting. The neutral switches as part of the 3P+N assembly, with three overcurrent-protected poles.

Where 100mA Sensitivity Is Specified

The 100mA rating is not interchangeable with 30mA additional protection requirements. Type A sensitivity does not by itself establish suitability for every EV charger or power-electronic load; follow equipment instructions.

Current Rating and Trip Response

The 50A overcurrent setting and 100mA residual-current threshold must be checked against circuit design. 100mA residual-current sensitivity is different from the 30mA additional protection required for certain installations. This is a C-curve product; substituting D curve changes the instantaneous-trip band and requires design verification.

Technical Specifications – Hager ASY450U 50A C Curve 100mA RCBO

Manufacturer Hager
Part number ASY450U
Device Electronic three-phase RCBO with switched neutral
Poles 3P+N; 3 overcurrent-protected phases
Rated current 50A
Trip characteristic C curve
Residual-current sensitivity 100mA
Residual-current class Type A
Rated breaking capacity 10kA
Module width 3 modules
Mounting DIN rail; compatible Hager Invicta distribution arrangement (verify board model)

Understanding B, C and D Trip Curves

B curve: typically 3–5 times rated current for instantaneous magnetic tripping, used for suitable low-inrush circuits. C curve: typically 5–10 times rated current, commonly specified for moderate inrush. D curve: typically 10–20 times rated current, considered for high-inrush loads such as some motors or transformers. Selected model: C curve. These bands describe magnetic tripping, not permissible continuous loading; the installed fault level and disconnection requirements must be verified.

The specific three-phase Hager range in this listing contains C- and D-curve models; no B-curve SKUs are included here.

Related Hager Three-Phase RCBOs

Compare ASY463U (63A, 100mA) or ASZ440U (C curve, 300mA) for a different rating or sensitivity.