VAT:

Consumer Units

Showing 401–420 of 476 results

Garo DPB1M-12 1 Module DPN RCBO Busbar – 12 Ways

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DPB1M-12
£19.48

Garo GS6S3C 3 Way SPD Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS6S3C
£48.33

Garo GS8S5C 5 Way SPD Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS8S5C
£53.42

Garo GS12S9C 9 Way SPD Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS12S9C
£55.38

Garo GS14S11C 11 Way SPD Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS14S11C
£57.65

Garo GS16S13C 13 Way SPD Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS16S13C
£59.76

Garo GS22S19C 19 Way SPD Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS22S19C
£66.66

Garo GS32S27C 27 Way SPD Dual Row Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS32S27C
£110.51

Garo GS36S31C 31 Way SPD Dual Row Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS36S31C
£113.54

Garo GS44S39C 39 Way SPD Dual Row Metal Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GS44S39C
£122.45

Garo GM5-5D 5 Module Metal IP65 Empty Enclosure

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GM5-5D
£27.04

Garo GCUT236 36 Module IP65 Dual Row Plastic Enclosure

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GCUT236
£64.50

Garo GM6-PS – 6 Module 40A Priority Electric Shower Board

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GM6-PS
£82.51

Garo GM10-PS63 – Metal 10 Module 63A/40A Priority Electric Shower Board

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GM10-PS63
£133.59

Garo GCS8HPB1 IP65 Plastic Consumer Unit for Heat Pumps with Type B RCD

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GCS8HPB1
£126.90

Garo GCS12HPB3 IP65 Plastic Consumer Unit for Heat Pumps with Type B RCD

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GCS12HPB3
£111.91

Switchtec | CURDP1 | 11 Way Consumer Unit Relocation Kit | 33 DIN Push-In Terminals | 2.5–10mm

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: CURDP1
£68.76

Switchtec | ESGU-40AT1661P | Garage Consumer Unit | 40A Type A RCD | 16A + 6A MCBs

1 In Stock
More available within:
Usually 1 - 3 Working Days
Read More
SKU: ESGU-40AT1661P
£21.99

Switchtec | ESSU-63AT501P | Shower Consumer Unit | 63A Type A RCD | 50A MCB

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: ESSU-63AT501P
£20.99

WCED Whitecliffe | WME36/SP | 36 Way | Metal Dual Row Consumer Unit | SPD

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WME36/SP
£83.76

Showing 401–420 of 476 results

What Is a Consumer Unit?

A consumer unit (also known as a fuse board) is the hub of your property’s electrical system. It distributes power to individual circuits and protects each one using devices such as MCBs, RCDs, or RCBOs.

All our units comply with the 18th Edition Wiring Regulations (BS 7671), including:

  • Non-combustible metal enclosures
  • RCBO or RCD circuit protection
  • SPD surge protection where required
  • Clear circuit labelling and safety markings

Whether you’re wiring a new build, upgrading an old fuse box, or adding capacity to a garage or extension, we’ve got a solution that works.

 

Our Range of Domestic Consumer Units

We stock over 280 configurations — here’s what you’ll find:

  • Main switch consumer units – clean, simple layouts
  • RCBO fuse boards – protection per circuit, no nuisance tripping
  • Garage consumer units – smaller units for outhouses or external installs
  • 18th Edition metal fuse boards – required by UK regulations
  • SPD-protected models – with built-in surge protection
  • Populated fuse boxes – pre-installed breakers, ready to go

We also carry a full range of accessories: blanking plates, SPD modules, tail kits, and more.

 

Why Buy From Electrical 4 Less?

We’re not just an online shop — we’re a real, UK-based electrical wholesaler with a Fulham trade counter and a strong customer base of electricians, landlords, and installers.

Thousands of customers have trusted us with their installs. You can too.

 

Explore Our Consumer Unit Categories

 

Follow Us Online

Get behind-the-scenes updates, product launches, and install tips:

  • YouTube – How-tos, demos, and product breakdowns
  • Instagram – New stock, installs, and trade gear
  • Facebook – Updates, support, and special offers

 

Frequently Asked Questions

What is a consumer unit?

A consumer unit (or fuse box) distributes electricity across your property and includes protective devices like RCBOs or RCDs to prevent faults and overloads.

Are all consumer units metal now?

Most domestic consumer units must be metal.
As per BS 7671 Regulation 421.1.201, units in domestic premises must be enclosed in non-combustible material when installed indoors. Plastic units are only permitted if housed inside a fully non-combustible cabinet that meets fire resistance standards.

Should I use RCBOs or RCDs?

RCBOs offer individual circuit protection, meaning one fault won’t take out all your power. They are now preferred for most modern installs.

What unit should I install in my garage?

Use a garage consumer unit – a compact, self-contained board with RCD or RCBO, ideal for outbuildings.

Can I install a consumer unit myself?

No. It must be installed or certified by a qualified electrician. This work is notifiable under Part P of UK Building Regulations.

Do I need surge protection?

Yes — especially for homes with expensive tech or sensitive electronics. Many new installs now require SPD units by default.

What’s the difference between Type A and Type AC RCDs?

Type A protects against both AC and pulsating DC faults. Type AC only covers AC faults — making them less suitable for modern homes.