VAT:

Circuit Protection

Showing 521–540 of 2375 results

Live Electrical LSMC14/100 100A Main Switch 12 Way Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: LSMC14/100
£32.64

Garo DCBO2MC40 30mA C Curve 40A Double Pole RCBO

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBO2MC40
£20.79

WCED WRT132B-030 Bi-Directional 10kA Type A 30mA RCBO Curve B 32A

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WRT132B-030
£10.97

Live Electrical | RTA2100-100 | 2 Pole | Time Delay Type A RCD | 6kA | 100mA | 100A

1 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: RTA2100-100
£28.50

WCED 12 Way Empty Plastic Enclosure

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WHA12-PME
Quantity Discount
Quantity Price
1 - 4 £20.68
5+ £20.16
10+ £19.65
20+ £19.13
£20.68

Fusebox SPDCUKITT1 Type 1,2 & 3 Surge Protection Device Kit

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: SPDCUKITT1
£109.00

Fusebox ABEC TPN Busbar End Caps (Pack of 30)

19 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: ABEC
£0.90

Live Electrical | RDA480-030 | 4 Pole | Bi-Directional Type A RCD | 6kA | 30mA | 80A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: RDA480-030
£19.99

WLB110 Monitoring Relay

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WCT24-100LB
£40.49

FuseBox | RTAMC25BD | 30mA | Curve C | Type A Bi-Directional Mini RCBO | 25A

20 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: RTAMC25BD
£14.34

Live Electrical RNA16C-030 RCBO A Type DP Bi-Directional 16A C Curve 30mA

4 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: RNA16C-030
£10.43

Live Electrical | CZ180C | 10kA | Curve C | 1 Pole Bi-Directional MCB | 80A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: CZ180C
£6.15

Hager CDB540HP 30mA 40A RCCB 1P+N Type B HP for Heat Pumps

1 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: CDB540HP
£146.98

Niglon PMAGNET Protego Consumer Unit Lid Magnet

28 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: PMAGNET
£1.15

Switchtec | CURDP2 | 20 Way Consumer Unit Relocation Kit | 60 DIN Terminals Push-In | 2.5–10mm

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: CURDP2
£99.99

Hager NCN116A Single Pole Type C MCB 16A 10kA

1 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: NCN116A
£9.18

Live Electrical MAC2P40 – 2 Pole 40A 2NO 230V AC Modular Contactor

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: MAC2P40
£9.79

FuseBox AFDD062030B 20A AFDD RCBO 30mA

1 In Stock
This item cannot be back-ordered
SKU: AFDD062030B
£70.99

Live Electrical | RDA463-030 | 4 Pole | Bi-Directional Type A RCD | 30mA | 63A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: RDA463-030
£22.50

WCED 12 Way Metal Enclosure

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WME12
Quantity Discount
Quantity Price
1 - 4 £25.72
5+ £25.08
10+ £24.43
20+ £23.79
£25.72

Showing 521–540 of 2375 results

Selection of Consumer Units, TPN Distribution Boards, Circuit Protection, Rotary Isolators, Meter Tails, Fused Switches and Accessories.

18th Edition Consumer Units with built in SPD Surge Protection Device, stand alone SPD units, PEN loss, PME fault detection consumer units, Consumer units relocation boxes/kits, Three phase distribution boards with built in SPD and main switch.

Thousands of products in stock ready for next day delivery. Friendly and reliable service, competitive prices.

Circuit protection in the UK is governed by the wiring regulations outlined in the British Standard BS 7671. This standard, also known as the IET Wiring Regulations, sets out the requirements for the design, installation, and maintenance of electrical installations in the UK. Circuit protection is a crucial aspect of electrical installations to ensure the safety of people and property.

Here are some key aspects of circuit protection according to BS 7671 and the devices commonly used in the UK market:

  1. Circuit Breakers: Circuit breakers are essential devices for protecting electrical circuits. BS 7671 specifies requirements for the selection and installation of circuit breakers. They come in various types, including:
    • Miniature Circuit Breakers (MCBs): MCBs are commonly used to protect individual circuits. They trip when there’s an overload or a short circuit.
    • Residual Current Devices (RCDs): RCDs are designed to protect against electric shock. They disconnect the circuit if they detect an imbalance in current, indicating a fault.
    • Combination RCD/MCB Devices: These devices combine the functions of both MCBs and RCDs in a single unit. They are often used for socket outlets.
  2. Fuses: While less common in modern installations, fuses may still be used for circuit protection. They work by melting when there’s an excess current, breaking the circuit.
  3. Overcurrent Protection: BS 7671 requires that circuits are protected against overcurrents. This is typically achieved through the use of circuit breakers, fuses, or other protective devices.
  4. Earthing and Bonding: Proper earthing and bonding are essential for safety. This ensures that in the event of a fault, the fault current is safely directed away from people and property.
  5. Surge Protection: Surge protection devices may be required to protect against voltage surges or lightning strikes, especially for sensitive electronic equipment.
  6. Arc Fault Detection: In certain installations, arc fault detection devices may be used to detect and disconnect circuits in the presence of dangerous arc faults.
  7. Circuit Isolation: BS 7671 also specifies requirements for circuit isolation devices such as switches and isolators.
  8. Cable Sizing: The standard provides guidelines for selecting the correct cable size to ensure that the cables can safely carry the intended load without overheating.
  9. Circuit Labels and Documentation: Proper labeling and documentation of circuits are important for maintenance and safety. BS 7671 outlines requirements for labeling and record-keeping.

It’s important to note that regulations and standards may be updated over time, so it’s essential to consult the latest version of BS 7671 and any local regulations or codes that may apply to your specific location or type of installation. Additionally, electrical work should be carried out by qualified and competent electricians to ensure compliance with safety standards.