VAT:

Circuit Protection

Showing 581–600 of 2375 results

FuseBox | RTA104030B | 10kA | 30mA | Curve B | Type A RCBO | 40A

22 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: RTA104030B
£15.99

Surge Devices LSPDPV1000 Type 1+2 SPD for 1000V PV Solar Panels

Available to Order
Estimated Lead Time:
Usually 3 - 4 Working Days
Read More
SKU: LSPDPV1000
Quantity Discount
Quantity Price
1 £180.00
2+ £176.40
3+ £174.60
£180.00

WCED 2 Pin 100A Busbar Pin Type – 13 Ways

9 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: BBP2100
£9.80

Live Electrical 19 Way SPD Metal Consumer Unit

3 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: LSMC22M-SP
Quantity Discount
Quantity Price
1 £55.87
2+ £54.75
3+ £53.91
£55.87

Live Electrical SP1401P+N/2 Type 2 SPD Surge Protection Device

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: SP1401P+N/2
£12.03

Live Electrical AGU4-SR/G IP65 Metal SPD Garage/EV Consumer Unit with B40A RCBO – Grey

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: AGU4-SR/G
Quantity Discount
Quantity Price
1 - 2 £52.92
3+ £51.60
5+ £50.27
10+ £48.95
£52.92

Live Electrical AGU4-SR/B IP65 Metal SPD Garage/EV Consumer Unit with B40A RCBO – Black

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: AGU4-SR/B
Quantity Discount
Quantity Price
1 - 2 £52.92
3+ £51.60
5+ £50.27
10+ £48.95
£52.92

FuseBox RTF400302 Type F RCD 40A 30mA 2P

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: RTF400302
£44.20

Live Electrical LSMC10/100 100A Main Switch 8 Way Consumer Unit

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: LSMC10/100
£27.52

Garo GCUT112 Empty 12 Module IP65 Enclosure

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: GCUT112
£23.19

Fusebox | EV40AXBD | EV Consumer Unit | Type 2 SPD | Main Switch with Bi-Directional RCBO | 40A

Out of Stock
This item cannot be back-ordered
SKU: EV40AXBD
£59.99

Live Electrical | RKA120B-030 | 1P+N | Bi-Directional RCBO | Type A | Curve B | 10kA | 30mA | 20A

19 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: RKA120B-030
£11.59

WCED 2 Pole 63A 100mA Time Delay Type A RCD

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: WARTD263-100
£28.93

Garo GP2100M 2 Way 100A Enclosure Meter Isolation Switch

28 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: GP2100M
£8.33

WCED | WRI3P32 | 32A | 3 Pole | DIN Rail Rotary Isolator Switch

13 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: WRI3P32
£9.12

Hager | ADB932R | 1P+N | 6kA | 30mA | B Curve | Type A Bidirectional RCBO | 32A

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ADB932R
£13.55

WCED | DEM1A001 | Bi-Directional Solar Generation Meter | Single Phase | 100A | MID Certified

5 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: DEM1A001
£22.10

Hager VM03CB Closed Top Wall Cable Protector Plate

8 In Stock
This item cannot be back-ordered
SKU: VM03CB
£1.50

Hager VM04CB 25mmx30mm Closed Meter Tail Plate

13 In Stock
This item cannot be back-ordered
SKU: VM04CB
£1.50

Fusebox AFMF18 18 Module Flush Mounting Frame Kit

2 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: AFMF18
£15.70

Showing 581–600 of 2375 results

Selection of Consumer Units, TPN Distribution Boards, Circuit Protection, Rotary Isolators, Meter Tails, Fused Switches and Accessories.

18th Edition Consumer Units with built in SPD Surge Protection Device, stand alone SPD units, PEN loss, PME fault detection consumer units, Consumer units relocation boxes/kits, Three phase distribution boards with built in SPD and main switch.

Thousands of products in stock ready for next day delivery. Friendly and reliable service, competitive prices.

Circuit protection in the UK is governed by the wiring regulations outlined in the British Standard BS 7671. This standard, also known as the IET Wiring Regulations, sets out the requirements for the design, installation, and maintenance of electrical installations in the UK. Circuit protection is a crucial aspect of electrical installations to ensure the safety of people and property.

Here are some key aspects of circuit protection according to BS 7671 and the devices commonly used in the UK market:

  1. Circuit Breakers: Circuit breakers are essential devices for protecting electrical circuits. BS 7671 specifies requirements for the selection and installation of circuit breakers. They come in various types, including:
    • Miniature Circuit Breakers (MCBs): MCBs are commonly used to protect individual circuits. They trip when there’s an overload or a short circuit.
    • Residual Current Devices (RCDs): RCDs are designed to protect against electric shock. They disconnect the circuit if they detect an imbalance in current, indicating a fault.
    • Combination RCD/MCB Devices: These devices combine the functions of both MCBs and RCDs in a single unit. They are often used for socket outlets.
  2. Fuses: While less common in modern installations, fuses may still be used for circuit protection. They work by melting when there’s an excess current, breaking the circuit.
  3. Overcurrent Protection: BS 7671 requires that circuits are protected against overcurrents. This is typically achieved through the use of circuit breakers, fuses, or other protective devices.
  4. Earthing and Bonding: Proper earthing and bonding are essential for safety. This ensures that in the event of a fault, the fault current is safely directed away from people and property.
  5. Surge Protection: Surge protection devices may be required to protect against voltage surges or lightning strikes, especially for sensitive electronic equipment.
  6. Arc Fault Detection: In certain installations, arc fault detection devices may be used to detect and disconnect circuits in the presence of dangerous arc faults.
  7. Circuit Isolation: BS 7671 also specifies requirements for circuit isolation devices such as switches and isolators.
  8. Cable Sizing: The standard provides guidelines for selecting the correct cable size to ensure that the cables can safely carry the intended load without overheating.
  9. Circuit Labels and Documentation: Proper labeling and documentation of circuits are important for maintenance and safety. BS 7671 outlines requirements for labeling and record-keeping.

It’s important to note that regulations and standards may be updated over time, so it’s essential to consult the latest version of BS 7671 and any local regulations or codes that may apply to your specific location or type of installation. Additionally, electrical work should be carried out by qualified and competent electricians to ensure compliance with safety standards.