Hager | ASZ410U | 3 Phase RCBO | 10kA | C Curve | 300mA Type A | 10A

SKU: ASZ410U
Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More

Hager ASZ410U 10A C Curve 300mA RCBO is a 10kA electronic 3P+N switched-neutral, three-module RCBO with Type A 300mA residual-current protection. C-curve response suits appropriately designed moderate-inrush circuits.

Hager ASZ410U 10A C Curve 300mA RCBO

The Hager ASZ410U 10A C Curve 300mA RCBO provides a 300mA Type A residual-current function alongside C-curve overcurrent protection. This sensitivity is normally considered within an engineered distribution or fire-risk protection strategy, not as a substitute for required 30mA additional protection.

Understanding the 300mA Rating

This 10A / 300mA combination is for protection designs where a 300mA residual threshold is appropriate. It must not be described or relied on as the same level of additional shock protection as a 30mA RCBO. A 300mA rating is not a substitute for 30mA additional protection on circuits where that is required.

Distribution-Circuit Selection

Type A sensitivity does not by itself establish suitability for every EV charger or power-electronic load; follow equipment instructions. This is a C-curve product; substituting D curve changes the instantaneous-trip band and requires design verification.

Technical Specifications – Hager ASZ410U 10A C Curve 300mA RCBO

Manufacturer Hager
Part number ASZ410U
Device Electronic three-phase RCBO with switched neutral
Poles 3P+N; 3 overcurrent-protected phases
Rated current 10A
Trip characteristic C curve
Residual-current sensitivity 300mA
Residual-current class Type A
Rated breaking capacity 10kA
Module width 3 modules
Mounting DIN rail; compatible Hager Invicta distribution arrangement (verify board model)

Understanding B, C and D Trip Curves

B curve: typically 3–5 times rated current for instantaneous magnetic tripping, used for suitable low-inrush circuits. C curve: typically 5–10 times rated current, commonly specified for moderate inrush. D curve: typically 10–20 times rated current, considered for high-inrush loads such as some motors or transformers. Selected model: C curve. These bands describe magnetic tripping, not permissible continuous loading; the installed fault level and disconnection requirements must be verified.

The specific three-phase Hager range in this listing contains C- and D-curve models; no B-curve SKUs are included here.

Related Hager Three-Phase RCBOs

Compare ASZ416U (16A, 300mA) or ASZ463U (C curve, 300mA) for a different rating or sensitivity.

Browse Hager Protection

Explore the Hager 3 phase RCBO range, Hager three-phase distribution boards and Hager shop.

Install and test in accordance with the Hager instructions and applicable wiring regulations. Verify the product-specific datasheet and board compatibility before ordering.