Hager | ASX416U | 3 Phase RCBO | 10kA | C Curve | 30mA Type A | 16A

SKU: ASX416U
Out of Stock
This item cannot be back-ordered

Hager ASX416U 16A C Curve 30mA RCBO is a 10kA electronic 3P+N switched-neutral, three-module RCBO with Type A 30mA residual-current protection. C-curve response suits appropriately designed moderate-inrush circuits.

Hager ASX416U 16A C Curve 30mA RCBO

The Hager ASX416U 16A C Curve 30mA RCBO is intended for three-phase final circuits requiring 30mA Type A residual-current protection. Its C-curve characteristic allows for moderate energisation current while maintaining combined overload and short-circuit protection.

C-Curve Operation and 30mA Protection

With a 16A rating and 30mA sensitivity, this version may suit appropriate commercial three-phase final circuits. C-curve magnetic operation is typically within 5–10 × In, or approximately 80–160A at this rating. A 30mA residual-current threshold may be used for additional protection where the circuit design and regulations require it.

Planning the Installation

Check that upstream protective-device coordination and required disconnection times can be achieved in the finished installation. This is a C-curve product; substituting D curve changes the instantaneous-trip band and requires design verification.

Technical Specifications – Hager ASX416U 16A C Curve 30mA RCBO

Manufacturer Hager
Part number ASX416U
Device Electronic three-phase RCBO with switched neutral
Poles 3P+N; 3 overcurrent-protected phases
Rated current 16A
Trip characteristic C curve
Residual-current sensitivity 30mA
Residual-current class Type A
Rated breaking capacity 10kA
Module width 3 modules
Mounting DIN rail; compatible Hager Invicta distribution arrangement (verify board model)

Understanding B, C and D Trip Curves

B curve: typically 3–5 times rated current for instantaneous magnetic tripping, used for suitable low-inrush circuits. C curve: typically 5–10 times rated current, commonly specified for moderate inrush. D curve: typically 10–20 times rated current, considered for high-inrush loads such as some motors or transformers. Selected model: C curve. These bands describe magnetic tripping, not permissible continuous loading; the installed fault level and disconnection requirements must be verified.

The specific three-phase Hager range in this listing contains C- and D-curve models; no B-curve SKUs are included here.

Related Hager Three-Phase RCBOs

Compare ASX420U (20A, 30mA) or ASY410U (C curve, 100mA) for a different rating or sensitivity.

Browse Hager Protection

Explore the Hager 3 phase RCBO range, Hager three-phase distribution boards and Hager shop.

Install and test in accordance with the Hager instructions and applicable wiring regulations. Verify the product-specific datasheet and board compatibility before ordering.