Niglon MS4CBR-160TSM 160A 4 Pole Enclosed CBR – MCCB + RCD Protection
The Niglon MS4CBR-160TSM 160A 4 Pole Enclosed CBR combines moulded case circuit breaker (MCCB) and residual current protection in a robust mild steel enclosure. Designed for three-phase commercial and industrial electrical distribution, this enclosed circuit breaker provides protection against overloads, short circuits and earth leakage faults.
With a 160A current rating, adjustable thermal protection and selectable residual current settings, the unit offers flexibility for electrical installations requiring coordinated circuit protection. Its IP30 enclosure, powder-coated finish and padlockable operating handle provide a practical solution for indoor switchgear applications.
Combined MCCB and RCD Protection
The enclosed CBR integrates four-pole MCCB functionality with earth leakage protection, eliminating the need for a separate residual current device where the combined protective characteristics are suitable.
Residual current sensitivity can be selected between 100mA, 300mA and 500mA, allowing settings to be chosen according to the installation requirements.
Adjustable time-delay settings of 50ms, 500ms and 800ms provide additional flexibility when designing protection coordination between upstream and downstream devices.
160A Four-Pole Circuit Protection
The Niglon MS4CBR-160TSM incorporates a four-pole MCCB rated at 160A, suitable for 400/415V AC three-phase systems.
Its adjustable thermal release provides flexibility for circuit loading requirements, while fixed magnetic protection responds to short-circuit fault conditions.
The associated Niglon 4CBR-160 device specification states a rated breaking capacity of 35kA at 415V and an ultimate short-circuit breaking capacity of 50kA at 400V AC.
Durable IP30 Mild Steel Enclosure
The CBR is supplied within a mild steel enclosure, finished in RAL7035 light grey epoxy powder coating.
The enclosure has an IP30 ingress protection rating when correctly installed and measures 500mm high x 400mm wide x 200mm deep.
A defeatable, padlockable operating handle allows the unit to be operated externally and secured in accordance with appropriate isolation procedures.
Key Features – Niglon MS4CBR-160TSM 160A 4 Pole Enclosed CBR
- 160A four-pole enclosed CBR combining MCCB and RCD functionality.
- Overload, short-circuit and residual current protection.
- 400/415V AC rated operational voltage.
- Adjustable thermal overload protection.
- Fixed magnetic short-circuit protection.
- Selectable earth leakage sensitivity: 100mA, 300mA or 500mA.
- Adjustable residual current time delay: 50ms, 500ms or 800ms.
- IP30 mild steel enclosure for suitable indoor applications.
- RAL7035 light grey epoxy powder-coated finish.
- Defeatable, padlockable operating handle.
- Enclosure dimensions: 500 x 400 x 200mm.
- Suitable for commercial and industrial three-phase distribution systems.
Technical Specifications – Niglon MS4CBR-160TSM 160A 4 Pole Enclosed CBR
| Manufacturer | Niglon |
|---|---|
| Product Code | MS4CBR-160TSM |
| Product Type | Enclosed CBR (MCCB + RCD) |
| Number of Poles | 4 Pole |
| Rated Current | 160A |
| Rated Operational Voltage | 400/415V AC |
| Rated Frequency | 50/60Hz |
| Rated Insulation Voltage | 750V |
| Rated Impulse Withstand Voltage | 8kV |
| Thermal Protection | Adjustable |
| Magnetic Protection | Fixed |
| Residual Current Settings | 100 / 300 / 500mA |
| Time Delay Settings | 50 / 500 / 800ms |
| Mechanical Endurance | 7,000 Operations |
| Electrical Endurance | 1,000 Operations |
| Enclosure Rating | IP30 |
| Enclosure Material | Mild Steel |
| Enclosure Dimensions | 500 x 400 x 200mm (H x W x D) |
| Enclosure Colour | RAL7035 Light Grey |
| Finish | Epoxy Powder Coated |
| Approximate Assembly Weight | 14kg |
| CBR Standard | IEC 60947-2 |
| Enclosure Standards | IEC 61439-1, IEC 62208, IEC 60529, IEC 62262 |
Typical Applications
The Niglon MS4CBR-160TSM 160A 4 Pole Enclosed CBR is designed for electrical installations requiring combined circuit breaker and earth leakage protection, including:
- Commercial three-phase electrical distribution.
- Industrial distribution boards and sub-main supplies.
- Electrical plant rooms and switchgear installations.
- Industrial machinery and fixed equipment supplies.
- Distribution systems requiring adjustable earth leakage protection.
Installation and Safety
Installation must be carried out by suitably qualified electrical personnel in accordance with current UK electrical installation regulations.
Residual current settings, circuit protection ratings and time-delay characteristics must be selected according to the installation design and protection coordination requirements.
Important: The minimum selectable residual current setting is 100mA. This product does not provide 30mA additional protection where such protection is required.
Correct cable glands must be used to maintain the enclosure’s ingress protection rating. All terminals should be checked for correct tightness before commissioning.