VAT:

Circuit Protection

Showing 1581–1600 of 2375 results

Live Electrical 1 Way Mushroom Head Stop Push Button with Key Reset

2 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: SPBKEY
£10.90

WCED Plastic Garage Unit – 100A Main Switch 6A/16A B MCB

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WPMS04/616
£21.53

WCED Plastic Garage Unit – 100A Main Switch 6A/20A B MCB

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WPMS04/620
£21.53

WCED | WMC110C | 6kA | Curve C | 1 Pole Bi-Directional MCB | 10A

9 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: WMC110C
£1.53

Hager ADA140U RCBO 10kA B-40A 30mA Type A

1 In Stock
This item cannot be back-ordered
SKU: ADA140U
£30.99

WCED Metal Dual 100A Type A RCD SPD Consumer Unit – 10 Usable Way

1 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: WME18100TR/SP
£91.63

WCED Metal Dual 100A Type A RCD Consumer Unit – 16 Usable Way

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WME22100TR
£84.28

Axiom TCF211 Auxiliary Contact Block

1 In Stock
This item cannot be back-ordered
SKU: TCF211
£3.95

Axiom TCL1 Mechanical Interlock

2 In Stock
This item cannot be back-ordered
SKU: TCL1
£5.07
Deligo Photovoltaic (Solar) DC Rotary Isolator Switch - 25ADeligo Photovoltaic (Solar) DC Rotary Isolator Switch - 25A 2

Deligo Photovoltaic (Solar) DC Rotary Isolator Switch – 25A

1 In Stock
This item cannot be back-ordered
SKU: DSRI25
£24.58 £19.99

Hager ARM906U AFD with MCB 6A Curve B

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARM906U
£81.25

Hager ARM910U AFD with MCB 10A Curve B

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARM910U
£81.25

Hager ARM916U AFD with MCB 16A Curve B

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARM916U
£81.25

Hager ARM920U AFD with MCB 20A Curve B

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARM920U
£81.25

Hager ARM925U AFD with MCB 25A Curve B

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARM925U
£81.25

Hager ARM932U AFD with MCB 32A Curve B

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARM932U
£81.25

Hager ARR906U AFD with 30mA RCBO 6A Curve B Type A

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARR906U
£92.96

Hager ARR910U AFD with 30mA RCBO 10A Curve B Type A

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARR910U
£92.96

Hager ARR925U AFD with 30mA RCBO 25A Curve B Type A

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ARR925U
£92.96

Europa Phase Failure Relay – 10A 220-460V AC

2 In Stock
This item cannot be back-ordered
SKU: ECPF08
£22.06

Showing 1581–1600 of 2375 results

Selection of Consumer Units, TPN Distribution Boards, Circuit Protection, Rotary Isolators, Meter Tails, Fused Switches and Accessories.

18th Edition Consumer Units with built in SPD Surge Protection Device, stand alone SPD units, PEN loss, PME fault detection consumer units, Consumer units relocation boxes/kits, Three phase distribution boards with built in SPD and main switch.

Thousands of products in stock ready for next day delivery. Friendly and reliable service, competitive prices.

Circuit protection in the UK is governed by the wiring regulations outlined in the British Standard BS 7671. This standard, also known as the IET Wiring Regulations, sets out the requirements for the design, installation, and maintenance of electrical installations in the UK. Circuit protection is a crucial aspect of electrical installations to ensure the safety of people and property.

Here are some key aspects of circuit protection according to BS 7671 and the devices commonly used in the UK market:

  1. Circuit Breakers: Circuit breakers are essential devices for protecting electrical circuits. BS 7671 specifies requirements for the selection and installation of circuit breakers. They come in various types, including:
    • Miniature Circuit Breakers (MCBs): MCBs are commonly used to protect individual circuits. They trip when there’s an overload or a short circuit.
    • Residual Current Devices (RCDs): RCDs are designed to protect against electric shock. They disconnect the circuit if they detect an imbalance in current, indicating a fault.
    • Combination RCD/MCB Devices: These devices combine the functions of both MCBs and RCDs in a single unit. They are often used for socket outlets.
  2. Fuses: While less common in modern installations, fuses may still be used for circuit protection. They work by melting when there’s an excess current, breaking the circuit.
  3. Overcurrent Protection: BS 7671 requires that circuits are protected against overcurrents. This is typically achieved through the use of circuit breakers, fuses, or other protective devices.
  4. Earthing and Bonding: Proper earthing and bonding are essential for safety. This ensures that in the event of a fault, the fault current is safely directed away from people and property.
  5. Surge Protection: Surge protection devices may be required to protect against voltage surges or lightning strikes, especially for sensitive electronic equipment.
  6. Arc Fault Detection: In certain installations, arc fault detection devices may be used to detect and disconnect circuits in the presence of dangerous arc faults.
  7. Circuit Isolation: BS 7671 also specifies requirements for circuit isolation devices such as switches and isolators.
  8. Cable Sizing: The standard provides guidelines for selecting the correct cable size to ensure that the cables can safely carry the intended load without overheating.
  9. Circuit Labels and Documentation: Proper labeling and documentation of circuits are important for maintenance and safety. BS 7671 outlines requirements for labeling and record-keeping.

It’s important to note that regulations and standards may be updated over time, so it’s essential to consult the latest version of BS 7671 and any local regulations or codes that may apply to your specific location or type of installation. Additionally, electrical work should be carried out by qualified and competent electricians to ensure compliance with safety standards.