VAT:

Circuit Protection

Showing 1261–1280 of 2483 results

Live Electrical | PSR/G | IP65 Auto Reset Push Button Switch | Green 1NO 1NC

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: PSR/G
£13.86

Hager | VME113SPD | Design Evo Consumer Unit Kit | Type 2 SPD | 13 Way | 9 RCBOs

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: VME113SPD/KIT/9RCBO
£201.29

FuseBox | DRISO633P | 3 Pole DIN Rail Isolator Switch | AC-23A | 63A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: DRISO633P
£26.44

FuseBox | FRIS4P063 | 4 Pole AC Rotary Isolator | IP65 | 63A

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: FRIS4P063
£20.53

Hager JK11003S 100A 3 Pole Mains Switch Incomer Kit

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: JK11003S
£42.88

Hager JK108BA3 125A 8 Way TPN Board with Plain Door (Amendment 3)

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: JK108BA3
£206.82

Live Electrical | TPN24-125S | 125A TP&N Distribution Board | 4P Main Switch | Type 2 SPD | 24 Way

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: TPN24-125S
£306.42

Live Electrical EN5050/250 IP65 Metal Enclosure H:500 x W:500 x D:250mm

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: EN5050/250
£82.21

Live Electrical | CEV463B-030 | 4 Pole | Bi-Directional Type B RCD | 10kA | 30mA | 63A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: CEV463B-030
£109.00

Live Electrical | RDA425-030 | 4 Pole | Bi-Directional Type A RCD | 30mA | 25A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: RDA425-030
£22.50

WCED WMGU04/620 Metal Garage Consumer Unit – 63A Type A RCD 6A/20A B MCBs

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WMGU04/620
Quantity Discount
Quantity Price
1 - 2 £25.30
3+ £24.67
5+ £24.04
10+ £23.40
£25.30

WCED Metal Garage Unit – 100A Main Switch 6A/16A B MCB

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WMMS/616
£20.04

WCED Metal Garage Unit – 100A Main Switch 6A/32A B MCB

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WMMS/632
£20.04

Live Electrical Double Pole Type A RCBO – Curve C – 10A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: RA210C-030
£13.99

WCED Double Pole Type A 30mA RCBO Curve C – 10A

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WER10C-030
£16.80

WCED Double Pole Type A 30mA RCBO Curve B – 6A

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WER06B-030
£15.09

Wago 788-516 Relay Module with 2 Changeover Contacts – 230V AC 8A 2.5mm² Grey

Available to Order
Estimated Lead Time:
Usually 3 - 5 Working Days
Read More
SKU: 788-516
£11.98

Fusebox TPN12FB 12 Way 125A Three Phase Board

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: TPN12FB
£229.95

FuseBox MT10D102 10A Double Pole 10kA D Curve MCB

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: MT10D102
£6.68

Hager JK112BG 125A 12 Way TPN Board Glazed Door

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: JK112BG
£207.39

Showing 1261–1280 of 2483 results

Selection of Consumer Units, TPN Distribution Boards, Circuit Protection, Rotary Isolators, Meter Tails, Fused Switches and Accessories.

18th Edition Consumer Units with built in SPD Surge Protection Device, stand alone SPD units, PEN loss, PME fault detection consumer units, Consumer units relocation boxes/kits, Three phase distribution boards with built in SPD and main switch.

Thousands of products in stock ready for next day delivery. Friendly and reliable service, competitive prices.

Circuit protection in the UK is governed by the wiring regulations outlined in the British Standard BS 7671. This standard, also known as the IET Wiring Regulations, sets out the requirements for the design, installation, and maintenance of electrical installations in the UK. Circuit protection is a crucial aspect of electrical installations to ensure the safety of people and property.

Here are some key aspects of circuit protection according to BS 7671 and the devices commonly used in the UK market:

  1. Circuit Breakers: Circuit breakers are essential devices for protecting electrical circuits. BS 7671 specifies requirements for the selection and installation of circuit breakers. They come in various types, including:
    • Miniature Circuit Breakers (MCBs): MCBs are commonly used to protect individual circuits. They trip when there’s an overload or a short circuit.
    • Residual Current Devices (RCDs): RCDs are designed to protect against electric shock. They disconnect the circuit if they detect an imbalance in current, indicating a fault.
    • Combination RCD/MCB Devices: These devices combine the functions of both MCBs and RCDs in a single unit. They are often used for socket outlets.
  2. Fuses: While less common in modern installations, fuses may still be used for circuit protection. They work by melting when there’s an excess current, breaking the circuit.
  3. Overcurrent Protection: BS 7671 requires that circuits are protected against overcurrents. This is typically achieved through the use of circuit breakers, fuses, or other protective devices.
  4. Earthing and Bonding: Proper earthing and bonding are essential for safety. This ensures that in the event of a fault, the fault current is safely directed away from people and property.
  5. Surge Protection: Surge protection devices may be required to protect against voltage surges or lightning strikes, especially for sensitive electronic equipment.
  6. Arc Fault Detection: In certain installations, arc fault detection devices may be used to detect and disconnect circuits in the presence of dangerous arc faults.
  7. Circuit Isolation: BS 7671 also specifies requirements for circuit isolation devices such as switches and isolators.
  8. Cable Sizing: The standard provides guidelines for selecting the correct cable size to ensure that the cables can safely carry the intended load without overheating.
  9. Circuit Labels and Documentation: Proper labeling and documentation of circuits are important for maintenance and safety. BS 7671 outlines requirements for labeling and record-keeping.

It’s important to note that regulations and standards may be updated over time, so it’s essential to consult the latest version of BS 7671 and any local regulations or codes that may apply to your specific location or type of installation. Additionally, electrical work should be carried out by qualified and competent electricians to ensure compliance with safety standards.