VAT:

Circuit Protection

Showing 901–920 of 2375 results

Hager JK11004S 100A 4 Pole Mains Switch Incomer Kit

1 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: JK11004S
£58.48

Hager NCN306A 3 Pole Type C MCB 6A 10kA

5 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: NCN306A
£38.80

Hager NCN340A 3 Pole MCB Type C 40A 10kA

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: NCN340A
£38.80

FuseBox INC254 – 4 Pole 25A 4NO 230V AC Modular Contactor

3 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: INC254
£10.89

Live Electrical EN5050/250 IP65 Metal Enclosure H:500 x W:500 x D:250mm

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: EN5050/250
£86.90

1.6mm-2.0mm Grommet PE Strip – 10 metres

2 In Stock
More available within:
Usually 1 - 3 Working Days
Read More
SKU: GS3/10M
£6.15

Live Electrical | CEV463B-030 | 4 Pole | Bi-Directional Type B RCD | 10kA | 30mA | 63A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: CEV463B-030
£109.00

Live Electrical | RDA425-030 | 4 Pole | Bi-Directional Type A RCD | 30mA | 25A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: RDA425-030
£22.50

WCED | WME14/MS100 | 100A Main Switch Consumer Unit | 12 Way

Out of Stock
15/07/26
Read More
SKU: WME14/MS100
£31.44

WCED WMGU04/620 Metal Garage Consumer Unit – 63A Type A RCD 6A/20A B MCBs

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WMGU04/620
Quantity Discount
Quantity Price
1 - 2 £25.30
3+ £24.67
5+ £24.04
10+ £23.40
£25.30

WCED Metal Garage Unit – 100A Main Switch 6A/32A B MCB

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WMMS/632
£20.04

WCED WAC2P40 – 2 Pole 40A 2NO 230V AC Modular Contactor

5 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: WAC2P40
Quantity Discount
Quantity Price
1 - 2 £10.95
3+ £10.68
5+ £10.40
10+ £10.13
20+ £9.85
£10.95

WCED Double Pole Type A 30mA RCBO Curve B – 6A

12 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: WER06B-030
£15.09

FuseBox MT10D201 20A Single Pole 10kA D Curve MCB

7 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: MT10D201
£3.22

FuseBox MT10D102 10A Double Pole 10kA D Curve MCB

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: MT10D102
£6.68

FuseBox MT10C063 6A Triple Pole 10kA C Curve MCB

15 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: MT10C063
£9.51

Fusebox ARCDLKTPN 4 Pole TPN RCD Link Fitting Kit

2 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: ARCDLKTPN
£6.50

Surge Devices 10811/LEDENCM Type 1+2+3 SPD – 3-Phase Lightning Arrester with 63A MCB in IP65 Enclosure for TN-S & TNC-S Systems

Available to Order
Estimated Lead Time:
Usually 3 - 4 Working Days
Read More
SKU: 10811/LEDENCM
£534.00

G-ProBox COMPAC-MET-100A-1PH-BI 100A Bi-Directional Single-Phase Modbus Compact Check Meter

6 In Stock
More available within:
Usually 1 - 3 Working Days
Read More
SKU: COMPAC-MET-100A-1PH-BI
£35.03

WARB5100C/PME 3 Phase Fault Detection Unit

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WARB5100C/PME
£66.70

Showing 901–920 of 2375 results

Selection of Consumer Units, TPN Distribution Boards, Circuit Protection, Rotary Isolators, Meter Tails, Fused Switches and Accessories.

18th Edition Consumer Units with built in SPD Surge Protection Device, stand alone SPD units, PEN loss, PME fault detection consumer units, Consumer units relocation boxes/kits, Three phase distribution boards with built in SPD and main switch.

Thousands of products in stock ready for next day delivery. Friendly and reliable service, competitive prices.

Circuit protection in the UK is governed by the wiring regulations outlined in the British Standard BS 7671. This standard, also known as the IET Wiring Regulations, sets out the requirements for the design, installation, and maintenance of electrical installations in the UK. Circuit protection is a crucial aspect of electrical installations to ensure the safety of people and property.

Here are some key aspects of circuit protection according to BS 7671 and the devices commonly used in the UK market:

  1. Circuit Breakers: Circuit breakers are essential devices for protecting electrical circuits. BS 7671 specifies requirements for the selection and installation of circuit breakers. They come in various types, including:
    • Miniature Circuit Breakers (MCBs): MCBs are commonly used to protect individual circuits. They trip when there’s an overload or a short circuit.
    • Residual Current Devices (RCDs): RCDs are designed to protect against electric shock. They disconnect the circuit if they detect an imbalance in current, indicating a fault.
    • Combination RCD/MCB Devices: These devices combine the functions of both MCBs and RCDs in a single unit. They are often used for socket outlets.
  2. Fuses: While less common in modern installations, fuses may still be used for circuit protection. They work by melting when there’s an excess current, breaking the circuit.
  3. Overcurrent Protection: BS 7671 requires that circuits are protected against overcurrents. This is typically achieved through the use of circuit breakers, fuses, or other protective devices.
  4. Earthing and Bonding: Proper earthing and bonding are essential for safety. This ensures that in the event of a fault, the fault current is safely directed away from people and property.
  5. Surge Protection: Surge protection devices may be required to protect against voltage surges or lightning strikes, especially for sensitive electronic equipment.
  6. Arc Fault Detection: In certain installations, arc fault detection devices may be used to detect and disconnect circuits in the presence of dangerous arc faults.
  7. Circuit Isolation: BS 7671 also specifies requirements for circuit isolation devices such as switches and isolators.
  8. Cable Sizing: The standard provides guidelines for selecting the correct cable size to ensure that the cables can safely carry the intended load without overheating.
  9. Circuit Labels and Documentation: Proper labeling and documentation of circuits are important for maintenance and safety. BS 7671 outlines requirements for labeling and record-keeping.

It’s important to note that regulations and standards may be updated over time, so it’s essential to consult the latest version of BS 7671 and any local regulations or codes that may apply to your specific location or type of installation. Additionally, electrical work should be carried out by qualified and competent electricians to ensure compliance with safety standards.