VAT:

Bi-Directional RCBOs

Showing 101–120 of 134 results

Garo DCBO1MC6 6A Curve C 1 Module 2 Pole Type A Bi-Directional RCBO

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBO1MC6
£19.99

Garo DCBO1MC16 16A Curve C 1 Module 2 Pole Type A Bi-Directional RCBO

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBO1MC16
£19.99

Garo DCBO1MC20 20A Curve C 1 Module 2 Pole Type A Bi-Directional RCBO

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBO1MC20
£19.99

Garo DCBO1MC25 25A Curve C 1 Module 2 Pole Type A Bi-Directional RCBO

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBO1MC25
£19.99

Garo DCBO1MC32 32A Curve C 1 Module 2 Pole Type A Bi-Directional RCBO

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBO1MC32
£19.99

Garo DCBOGRB10-BI 30mA Bi-Directional Type A Compact RCBO 10A B Curve

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBOGRB10-BI
£14.99

Garo DCBOGRB16-BI 30mA Bi-Directional Type A Compact RCBO 16A B Curve

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBOGRB16-BI
£14.99

Garo DCBOGRB25-BI 30mA Bi-Directional Type A Compact RCBO 25A B Curve

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBOGRB25-BI
£14.99

Hager | ADB925R | 1P+N | 6kA | 30mA | B Curve | Type A Bidirectional RCBO | 25A

Available to Order
Estimated Lead Time:
Usually 2 - 4 Working Days
Read More
SKU: ADB925R
£13.55

Garo RCBOGSC32 32A C Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSC32
£74.90
Read more

Timeguard | TX2516 | B Curve | 6kA | Type A Bi-Directional RCBO | 16A

Out of Stock
This item cannot be back-ordered
SKU: TX2516
£15.10
Read more

Timeguard | TX2532 | B Curve | 6kA | Type A Bi-Directional RCBO | 32A

Out of Stock
This item cannot be back-ordered
SKU: TX2532
£15.10
Read more

Garo RCBOGSB10 10A B Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSB10
£74.90
Read more

Garo RCBOGSB16 16A B Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSB16
£74.90
Read more

Garo RCBOGSB20 20A B Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSB20
£74.90
Read more

Garo RCBOGSB25 25A B Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSB25
£74.90
Read more

Garo RCBOGSB32 32A B Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSB32
£74.90
Read more

Garo RCBOGSC10 10A C Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSC10
£74.90
Read more

Garo RCBOGSC16 16A C Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSC16
£74.90
Read more

Garo RCBOGSC20 20A C Curve Type A 4 Pole 3 Phase Bi-Directional RCBO

Out of Stock
This item cannot be back-ordered
SKU: RCBOGSC20
£74.90
Read more

Showing 101–120 of 134 results

Understanding Bi-Directional RCBOs

Bi-Directional RCBOs represent a key advancement in circuit protection, offering reliable safety in both directions of current flow. Traditional RCBOs were designed primarily for current moving from the supply to the load, but as modern electrical systems evolved — with energy generation and storage becoming commonplace — this limitation needed to be addressed.

Why Bi-Directional RCBOs Were Introduced

With the rise of solar PV systems, EV chargers, and battery storage, current can flow back toward the supply side under certain conditions.
Standard RCBOs may not detect faults accurately in these situations, which led to the development of bidirectional designs — devices that sense and interrupt earth leakage and overcurrent faults regardless of current direction.

This makes them ideal for use in:

  • EV charging installations
  • Solar and battery hybrid systems
  • Smart homes with distributed power sources.

 

Compliance and BS 7671 Requirements

The 18th Edition Wiring Regulations (BS 7671) emphasise the importance of using suitable protective devices for circuits where current flow may reverse.
Bi-Directional RCBOs help ensure compliance with these standards, reducing the risk of faults in renewable and energy-efficient systems.

Their dual-direction sensing technology ensures protection for both installers and end users, helping future-proof electrical installations in line with Part 7: Section 722 (Electric Vehicle Charging Installations) and Regulation 712.411.3.2.1.1 (Solar PV Systems).

 

Frequently Asked Questions

What makes an RCBO bi-directional?

A bi-directional RCBO can detect and interrupt residual current faults in both directions of current flow — from supply to load and load to supply. This is vital in systems where current may reverse, such as solar PV or battery storage setups.

Do I need a bi-directional RCBO for my EV charger?

Yes, in most cases. BS 7671 (18th Edition) recommends using bi-directional protection for circuits that can export energy back into the system, which applies to many EV charging and renewable energy applications. It ensures the installation remains safe and compliant.

Are bi-directional RCBOs interchangeable with standard RCBOs?

Physically, they fit the same consumer units, but not all systems require them. Standard RCBOs protect only one direction of current flow, while bi-directional versions are designed for bidirectional power environments. Always check your manufacturer’s instructions and regulation requirements before replacing.