VAT:

Circuit Protection

Showing 761–780 of 2380 results

Hager ECR140D 1 Phase kWh Meter Direct 40A 1M MODBUS MID

3 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: ECR140D
£112.37

Hager | ADB445G | 1P+N | 6kA | 30mA | B Curve | Type A RCBO | 45A

5 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: ADB445G
£13.55

Hager ADB410U RCBO 10kA B-10A 30mA Type A

18 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: ADB410U
£37.99

Hager ADC406U RCBO 10kA C-6A 30mA Type A

8 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: ADC406U
£37.99

Hager ADC420U RCBO 10kA C-20A 30mA Type A

2 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: ADC420U
£37.99
Hager JK116EG Hager JK116EG 16 Module Din Rail Extension Box with Glazed DoorHager JK116EG 16 Module Din Rail Extension Box with Glazed Door

Hager JK116EG 16 Module Din Rail Extension Box with Glazed Door

1 In Stock
This item cannot be back-ordered
SKU: JK116EG
£115.79 £103.38
Hager JK106BG 125A 6 Way TPN Board Glazed Door

Hager JK106BG 125A 6 Way TPN Board Glazed Door

1 In Stock
This item cannot be back-ordered
SKU: JK106BG
£154.41 £137.87
Live Electrical LSGU63620 Live Electrical LSGU63620 Garage 63A RCD Consumer Unit with 6A&20A MCBs

Live Electrical LSGU63620 Garage 63A RCD Consumer Unit with 6A&20A MCBs

1 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: LSGU63620
£32.84 £31.55

Live Electrical AGU5-SR/G IP65 Metal SPD 2 Way Garage/EV Unit with B40A RCBO – Grey

1 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: AGU5-SR/G
Quantity Discount
Quantity Price
1 - 2 £52.92
3+ £51.60
5+ £50.27
10+ £48.95
£52.92
Live Electrical LEV432SP-P IP65 EV Consumer Unit C32 RCBO + Type 2 SPD + BusbarLive Electrical LEV432SP-P IP65 EV Consumer Unit C32 RCBO + Type 2 SPD + Busbar 2

Live Electrical LEV432SP-P IP65 EV Consumer Unit C32 RCBO + Type 2 SPD + Busbar

21 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: LEV432SP-P
Quantity Discount
Quantity Price
1 - 2 £30.99
3+ £29.44
5+ £28.67
10+ £26.96
20+ £25.41
£30.99

Hager KF82A Connection Terminal 1P Prong 2 Cable 16mm² – Pack of 1

7 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: KF82A
£6.92

Live Electrical 3P+N 10A B Curve 30mA Type A RCBO

5 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: RTN310B-030N
£45.15

Live Electrical 3P+N 25A B Curve 30mA Type A RCBO

2 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: RTN325B-030N
£45.15

Live Electrical MS4100D 4 Pole 100A Double Terminal Main Switch

2 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: MS4100D
£12.06

Live Electrical LS-MB08 8 Module LSMC Mounting Bracket

4 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: LS-MB08
£7.17

Live Electrical LS-MB12 12 Module LSMC Mounting Bracket

6 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: LS-MB12
£7.88

Hager KDN363B Insulated Busbar 3P 63A Fork 10mm² 57M

1 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: KDN363B
£55.02

Hager KZ023A End Caps for 2P and 3P Busbars (Pack of 10)

4 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: KZ023A
£5.99

Niglon M3CU10SP 100A DP Main Switch 6 Way SPD Consumer Unit

1 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: M3CU10SP
£59.14

Gewiss GW70488P 25A 4-Pole IP66/67/69 Rotary Isolator Switch

7 In Stock
This item cannot be back-ordered
SKU: GW70488P
£15.79

Showing 761–780 of 2380 results

Selection of Consumer Units, TPN Distribution Boards, Circuit Protection, Rotary Isolators, Meter Tails, Fused Switches and Accessories.

18th Edition Consumer Units with built in SPD Surge Protection Device, stand alone SPD units, PEN loss, PME fault detection consumer units, Consumer units relocation boxes/kits, Three phase distribution boards with built in SPD and main switch.

Thousands of products in stock ready for next day delivery. Friendly and reliable service, competitive prices.

Circuit protection in the UK is governed by the wiring regulations outlined in the British Standard BS 7671. This standard, also known as the IET Wiring Regulations, sets out the requirements for the design, installation, and maintenance of electrical installations in the UK. Circuit protection is a crucial aspect of electrical installations to ensure the safety of people and property.

Here are some key aspects of circuit protection according to BS 7671 and the devices commonly used in the UK market:

  1. Circuit Breakers: Circuit breakers are essential devices for protecting electrical circuits. BS 7671 specifies requirements for the selection and installation of circuit breakers. They come in various types, including:
    • Miniature Circuit Breakers (MCBs): MCBs are commonly used to protect individual circuits. They trip when there’s an overload or a short circuit.
    • Residual Current Devices (RCDs): RCDs are designed to protect against electric shock. They disconnect the circuit if they detect an imbalance in current, indicating a fault.
    • Combination RCD/MCB Devices: These devices combine the functions of both MCBs and RCDs in a single unit. They are often used for socket outlets.
  2. Fuses: While less common in modern installations, fuses may still be used for circuit protection. They work by melting when there’s an excess current, breaking the circuit.
  3. Overcurrent Protection: BS 7671 requires that circuits are protected against overcurrents. This is typically achieved through the use of circuit breakers, fuses, or other protective devices.
  4. Earthing and Bonding: Proper earthing and bonding are essential for safety. This ensures that in the event of a fault, the fault current is safely directed away from people and property.
  5. Surge Protection: Surge protection devices may be required to protect against voltage surges or lightning strikes, especially for sensitive electronic equipment.
  6. Arc Fault Detection: In certain installations, arc fault detection devices may be used to detect and disconnect circuits in the presence of dangerous arc faults.
  7. Circuit Isolation: BS 7671 also specifies requirements for circuit isolation devices such as switches and isolators.
  8. Cable Sizing: The standard provides guidelines for selecting the correct cable size to ensure that the cables can safely carry the intended load without overheating.
  9. Circuit Labels and Documentation: Proper labeling and documentation of circuits are important for maintenance and safety. BS 7671 outlines requirements for labeling and record-keeping.

It’s important to note that regulations and standards may be updated over time, so it’s essential to consult the latest version of BS 7671 and any local regulations or codes that may apply to your specific location or type of installation. Additionally, electrical work should be carried out by qualified and competent electricians to ensure compliance with safety standards.