VAT:

Circuit Protection

Showing 401–420 of 2375 results

FuseBox F3021MZ 21 Way RCBO Consumer Unit With SPD

2 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: F3021MZ
Quantity Discount
Quantity Price
1 - 3 £67.95
4+ £65.57
£67.95

SW100-STEEL & SW100-12MM-STEEL Sealing Ferrules with Galvanised Wire

Available to Order
Estimated Lead Time:
Usually 1 - 3 Working Days
Read More
SKU: SW150-12MM-STEEL
£21.00

Garo DCBOGRC16 30mA Type A Compact RCBO 16A C Curve

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DCBOGRC16
£10.99

Live Electrical MS4100 4 Pole 100A Main Switch

7 In Stock
More available within:
Usually 2 - 3 Working Days
Read More
SKU: MS4100
£9.07

Live Electrical Metal Enclosure IP65 H:1000 x W:800 x D:300mm

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: EN10080/300
£258.39

Live Electrical Single Pole 32A Rail Mount Fuse Holder Without Fuse

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: WS18-32
£2.50

WCED | WME18/SP | SPD Consumer Unit | 15 Way

1 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: WME18/SP
£46.96

WCED | WMC150B | 6kA | Curve B | 1 Pole Bi-Directional MCB | 50A

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WMC150B
£1.37

Live Electrical Double Pole Type A RCBO – Curve C – 40A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: RA240C-030
£13.99

Fusebox TPN11FBX 11 Way 125A Three Phase Board with SPD

3 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: TPN11FBX
£230.15

Live Electrical Double Pole 63A Copper Busbar 1m 10mm² 108 Pin

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: DPN63A
£8.85

FuseBox | RTA064530B | 6kA | 30mA | Curve B | Type A RCBO | 45A

74 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: RTA064530B
£9.99

WCED Consumer Unit Kit with SPD and 5 RCBOs

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WME10/SP/5RCBO
£79.33

FuseBox | RTAMB10BD | 30mA | Curve B | Type A Bi-Directional Mini RCBO | 10A

54 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: RTAMB10BD
£14.34

FuseBox MT06C061 6A MCB Curve C

41 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: MT06C061
£1.95

Live Electrical | RDA440-030 | 4 Pole | Bi-Directional Type A RCD | 6kA | 30mA | 40A

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: RDA440-030
£22.50

WCED WAC2P32 – 2 Pole 32A 2NO 230V AC Modular Contactor

3 In Stock
More available within:
Usually 1 - 2 Working Days
Read More
SKU: WAC2P32
Quantity Discount
Quantity Price
1 - 2 £6.22
3+ £6.06
5+ £5.91
10+ £5.75
20+ £5.60
£6.22

WCED A-Type Electric Vehicle 2 Module Enclosure – 32A RCBO B Curve

Available to Order
Estimated Lead Time:
Usually 1 - 2 Working Days
Read More
SKU: WMEV232B
£25.99

Live Electrical SC440 4 Pole 20kA/40kA Type 2 SPD Surge Protective Device

Available to Order
Estimated Lead Time:
Usually 2 - 3 Working Days
Read More
SKU: SC440
£37.55

FuseBox | RTAMC40BD | 30mA | Curve C | Type A Bi-Directional Mini RCBO | 40A

23 In Stock
More available within:
Usually 2 - 4 Working Days
Read More
SKU: RTAMC40BD
£14.34

Showing 401–420 of 2375 results

Selection of Consumer Units, TPN Distribution Boards, Circuit Protection, Rotary Isolators, Meter Tails, Fused Switches and Accessories.

18th Edition Consumer Units with built in SPD Surge Protection Device, stand alone SPD units, PEN loss, PME fault detection consumer units, Consumer units relocation boxes/kits, Three phase distribution boards with built in SPD and main switch.

Thousands of products in stock ready for next day delivery. Friendly and reliable service, competitive prices.

Circuit protection in the UK is governed by the wiring regulations outlined in the British Standard BS 7671. This standard, also known as the IET Wiring Regulations, sets out the requirements for the design, installation, and maintenance of electrical installations in the UK. Circuit protection is a crucial aspect of electrical installations to ensure the safety of people and property.

Here are some key aspects of circuit protection according to BS 7671 and the devices commonly used in the UK market:

  1. Circuit Breakers: Circuit breakers are essential devices for protecting electrical circuits. BS 7671 specifies requirements for the selection and installation of circuit breakers. They come in various types, including:
    • Miniature Circuit Breakers (MCBs): MCBs are commonly used to protect individual circuits. They trip when there’s an overload or a short circuit.
    • Residual Current Devices (RCDs): RCDs are designed to protect against electric shock. They disconnect the circuit if they detect an imbalance in current, indicating a fault.
    • Combination RCD/MCB Devices: These devices combine the functions of both MCBs and RCDs in a single unit. They are often used for socket outlets.
  2. Fuses: While less common in modern installations, fuses may still be used for circuit protection. They work by melting when there’s an excess current, breaking the circuit.
  3. Overcurrent Protection: BS 7671 requires that circuits are protected against overcurrents. This is typically achieved through the use of circuit breakers, fuses, or other protective devices.
  4. Earthing and Bonding: Proper earthing and bonding are essential for safety. This ensures that in the event of a fault, the fault current is safely directed away from people and property.
  5. Surge Protection: Surge protection devices may be required to protect against voltage surges or lightning strikes, especially for sensitive electronic equipment.
  6. Arc Fault Detection: In certain installations, arc fault detection devices may be used to detect and disconnect circuits in the presence of dangerous arc faults.
  7. Circuit Isolation: BS 7671 also specifies requirements for circuit isolation devices such as switches and isolators.
  8. Cable Sizing: The standard provides guidelines for selecting the correct cable size to ensure that the cables can safely carry the intended load without overheating.
  9. Circuit Labels and Documentation: Proper labeling and documentation of circuits are important for maintenance and safety. BS 7671 outlines requirements for labeling and record-keeping.

It’s important to note that regulations and standards may be updated over time, so it’s essential to consult the latest version of BS 7671 and any local regulations or codes that may apply to your specific location or type of installation. Additionally, electrical work should be carried out by qualified and competent electricians to ensure compliance with safety standards.