Timeguard Valiance+ RCD Protected Passive Single Gang Fused Connection Unit – White

SKU: RCD10WPVN

Dispatch 3-5 Days

Type A RCDs

Conforms to BS7288:2016 BS1363-2, and meets latest IET Wiring Regulations

Continues to protect with Lost Neutral /pulsating DC earth fault

Designed, Tested and Certified in the UK

High EMC Immunity dramatically reduces nuisance tripping

£19.45 + VAT

(incl. VAT £23.34)

Dispatch Info
This product will be ordered from one of ours suppliers. The usual dispatch time to you is displayed above. You will receive a notification if there are any delays once your order is placed.
Category: Tag:

Description

Timeguard Valiance+ RCD Protected Passive Single Gang Fused Connection Unit – White

Stay Safe with Valiance+. Dual Flag Technology provides extra protection against the risks of electrocution.

Timeguard’s new ‘Dual Flag RCD Technology’ is a brand new safety feature stipulated in the latest BS7288:2016 standard. It provides additional safety to both the installer and end user by showing clear visual indication as to the status of the RCD. A RED flag shows the device is ON with a live supply to the appliance. A GREEN flag shows the device is safe with the supply to the appliance switched OFF. For added safety and reliability, Timeguard have used an innovative mechanical flag system due to LED indication systems being less reliable and having a limited life.

Timeguard’s new range of Valiance Plus RCDs are fully approved and certified to the new BS7288:2016 standard which now demands a higher resilience to RF devices (EG: mobile phones, walkie-talkies, electronic equipment, etc.), resulting in lower nuisance tripping compared to RCDs built to the old BS standard.

  • New Dual Flag Technology provides added protection against the risks of electrocution
  • High EMC Immunity dramatically reduces nuisance tripping
  • Conforms to BS7288:2016 BS1363-2, and meets latest IET Wiring Regulations
  • Continues to protect with Lost Neutral /pulsating DC earth fault
  • Designed, Tested and Certified in the UK
  • Type A RCDs
Operating Voltage 230V AC
Frequency 50Hz
Installation Type Surface/Recessed
Earth Class Rating Class I
Operating Temperature -5°C to 40°C
Back Box Minimum Depth (mm) 25
Operational Classification Latching (Passive)
Rated Trip Current 30mA
Trip Speed Less than 40msec at 150mA residual current
Mounting Hole Centres (mm) 60
Body Construction Thermoset
Dimensions Height 85mm
Width 85mm
Depth 52mm