Hager VMLA90810HSPD 8+10 Way Dual Row Dual RCD Consumer Unit + Arc Fault Protection & SPD - Electrical 4 Less
Electrical 4 Less
delivery-note
FREE DELIVERY
on orders over  £49.99  + VAT
UK Mainland Only
Lighting
Design
trustpilot-grade Trustpilot • Excellent
delivery note
FREE DELIVERY
on orders over  £49.99  + VAT
UK Mainland Only
Hager VMLA90810HSPD 8+10 Way Dual Row Dual RCD Consumer Unit + Arc Fault Protection & SPD
SKU: VMLA90810HSPD

Dispatch 3-5 Days

18th Edition Regulation 421.1.7 Arc-Fault Protection Compliant

Supplied with 100A main switch and 2 x 100A 30mA Type A RCCBs

Double Pole Busbar System for AFDD

Includes Surge Protection Device

Conforms to BS EN 61439-3

£534.50 + VAT

(incl. VAT £641.40)

This product will be ordered from one of ours suppliers. The usual dispatch time to you is displayed above. You will receive a notification if there are any delays once your order is placed.

Depth: 100 mm Heigh: 486 mm Width: 478 mm

Dual Row – 18 Useable Ways

100A Main Switch

2 no 100A 30mA Type A RCCB’s

SPD Surge Protection Device

x

Description

Hager VMLA90810HSPD 8+10 Way Dual Row Dual RCD Consumer Unit + Arc Fault Protection & SPD

This Hager Consumer Unit has double pole busbar to house ARC Protection Devices.

Hager Arc-Fault Detection Devices are a new fire prevention modules. Each modules combines MCB overcurrent protective device and Arc Protection.

The range of consumer units with a 100A rated current (InA) have been designed for installations where the upstream overcurrent protection device (OCPD) is rated at 100A or below.

Designed for use with Arc Fault Detection Devices the board contains double pole busbars to allow the connection of these devices.Earth leakage protection is provided by 100 A, 30 mA type A RCCBs. Designed for all applications and allows compliance with BS 7671:2018;

Regulation 421.1.201 within domestics (household) applications consumer units and similar assemblies shall comply with BS EN 61439-3 and shall have their enclosure manufactured from a non-combustible material.

Regulation 411.3.3 additional protection by means of a 30mA RCD. Regulation 314.1&2 segregation of circuits to avoid danger and minimise inconvenience in the event of a fault.

Regulation 522.6.202 protection of wiring concealed in walls or partitions.

Regulation 531.3.3 Selection of appropriate RCD. Type A RCCBs can detect and respond to both AC and pulsating DC components.

Regulation 536.4.3.2 & 536.4.202 overload protection of switches and RCCBs. For installations where the upstream overcurrent protection is less than or equal to 100 A

A split load board allows circuits to be arranged in a configuration to minimise inconvenience to the householder in case of an earth leakage fault.

For our full range of Hager consumer units click here

Additional information

Brand
Hager
Consumer Unit Type
AFDD, Dual Row
Range
Design 10
Mounting
Surface

You may also like…

Hager ARC916U AFDD MCB with ARC Protect Detection Type B 16A

Dispatch 3-5 Days
SKU: ARC916U

£94.51 £113.41

Hager ARC906U AFDD MCB with ARC Protect Detection Type B 6A

Dispatch 3-5 Days
SKU: ARC906U

£94.51 £113.41

Hager ARC920U AFDD MCB with ARC Protect Detection Type B 20A

Dispatch 3-5 Days
SKU: ARC920U

£94.51 £113.41

Hager ARC910U AFDD MCB with ARC Protect Detection Type B 10A

Dispatch 3-5 Days
SKU: ARC910U

£94.51 £113.41

Hager ARC940U AFDD MCB with ARC Protect Detection Type B 40A

Dispatch 3-5 Days
SKU: ARC940U

£94.51 £113.41

Hager ARC925U AFDD MCB with ARC Protect Detection Type B 25A

Dispatch 3-5 Days
SKU: ARC925U

£94.51 £113.41

Hager ARC932U AFDD MCB with ARC Protect Detection Type B 32A

Dispatch 3-5 Days
SKU: ARC932U

£94.51 £113.41